Strovia’s own check
The same cohort reference twice
Finding CTL-02 of the free validator
Why it matters
The receiver identifies cohorts by refKey; two cohorts with the same key overwrite or mix each other's data. The SIVI schema cannot detect this. This is a Strovia platform check, not an official SIVI rule.
Example
What the validator says about a test message:
- What is wrong
- Cohort refKey COH-20-24 is used twice in scheme SPR-01 (cohorts 1 and 18).
- Where
- Scheme SPR-01, cohort 18, field refKey.
- How to fix it
- Give every cohort of the scheme its own refKey in the source data.
Check a message with the free validatorAll validation errors
Bron: SIVI – VB-PUO Standaard, Release 2027 (v1.4.0).